(626) 213-0054  |  Mon–Fri 8am–6pm PT  |  FREE SHIPPING
AEKONAMI — Protection You Can Trust.

Isolation Gown Guide

PP vs. SMS Isolation Gowns: Materials and AAMI Levels Explained

Isolation gown terminology can be confusing. This guide explains the differences between PP, PP+PE, SMS, SMMS, and SMMMS materials, how AAMI Levels 1 through 4 are tested, and what buyers should verify when selecting a gown.

Quick answer: What is the difference between PP and SMS isolation gowns?

PP usually refers to a nonwoven polypropylene fabric, often made by a spunbond process. It is commonly valued for being lightweight and economical. However, the term "PP gown" is broad: fabric weight, treatment, seams, closures, coverage, and finished-garment testing can vary.

SMS stands for spunbond–meltblown–spunbond. It is a layered nonwoven construction, usually made from polypropylene. The two spunbond outer layers contribute strength and structure, while the finer-fiber meltblown middle layer changes the material's barrier and filtration characteristics.

Neither label tells the whole story. An SMS gown is not automatically AAMI Level 2, 3, or 4, and a PP gown cannot be assigned a protection level from its name alone. For medical or infection-control use, look for the finished gown's intended use, AAMI PB70 classification, applicable test results, critical-zone coverage, seam performance, and manufacturer instructions.

Key distinction

PP, SMS, SMMS, and SMMMS describe material construction. AAMI levels describe tested barrier performance of the finished gown. One does not automatically prove the other.

Why gown terminology is confusing

Manufacturers and sellers may describe gowns by raw material, layer structure, coating, basis weight, intended use, or barrier level—sometimes all at once. Those descriptions answer different questions:

  • Material terms such as PP, PE, SMS, SMMS, and SMMMS describe how a fabric or laminate is constructed.
  • Performance classifications such as AAMI Level 1, 2, 3, or 4 describe how the finished protective apparel performed under specified tests.
  • Product type—for example, non-surgical isolation gown, surgical isolation gown, or surgical gown—affects intended use and regulatory expectations.
  • Design details such as coverage, cuffs, ties, seams, and closures affect how the finished garment functions in practice.

That is why a responsible comparison cannot rank gowns by acronym alone.

PP, PE, PP+PE, SMS, SMMS, and SMMMS explained

PP: polypropylene nonwoven

Polypropylene is a synthetic polymer widely used in disposable protective apparel. In many gown descriptions, "PP" means a spunbond polypropylene nonwoven. Spunbond fibers form a web that is bonded into fabric, providing structure and strength at relatively low weight.

Typical advantages include low weight, economical production, and comfortable drape. Barrier performance can vary substantially with fabric weight, repellency treatments, construction, seams, and garment design. "Made from polypropylene" is therefore a material fact, not proof of a particular fluid-barrier level.

PE: polyethylene film

Polyethylene is commonly used as a film or coating. A continuous film can increase resistance to liquid penetration, but it may also reduce air and moisture-vapor movement. Comfort depends on film thickness, where it is used, and how the overall gown is designed.

PP+PE: polypropylene combined with polyethylene

PP+PE generally describes a polypropylene nonwoven combined with a polyethylene film or coating. The PP layer contributes structure; the PE component is used to increase liquid resistance. Construction varies: a product may be fully coated, laminated, or reinforced only in selected areas.

Do not assume that every PP+PE gown is waterproof or has the same comfort. Verify the finished garment's test results and which zones contain film or reinforcement.

SMS: spunbond–meltblown–spunbond

SMS is a three-part composite:

LayerRole in the construction
Spunbond outer layerStrength, abrasion resistance, and structure
Meltblown middle layerA fine-fiber layer that changes barrier and filtration characteristics
Spunbond outer layerStrength, surface durability, and structure

SMS construction is often selected when designers want a balance of strength, low weight, breathability, and liquid-resistance performance. The actual balance depends on basis weight, fiber and pore structure, bonding, surface treatment, seams, and finished-garment design.

SMMS and SMMMS

The letters show the layer sequence:

  • SMMS: spunbond–meltblown–meltblown–spunbond
  • SMMMS: spunbond–meltblown–meltblown–meltblown–spunbond

Additional meltblown layers can let a manufacturer distribute fine fibers differently within a composite. But more "M" letters do not automatically mean a higher AAMI level, a universally better gown, or a fixed amount of protection. Performance still depends on the complete fabric system and the finished garment's tested construction.

Isolation gown material comparison

ConstructionWhat it meansCommon design strengthsWhat a buyer should verify
Spunbond PPNonwoven polypropylene, often a single spunbond webLightweight, economical, flexibleFabric weight and treatment; intended use; coverage; seam and finished-garment test data
PP+PEPP nonwoven combined with PE film or coatingIncreased liquid resistance in coated or laminated areasFull or partial film coverage; breathability; seam construction; applicable barrier tests
SMSSpunbond–meltblown–spunbond compositeBalance of strength, low weight, breathability, and barrier designBasis weight; repellency treatment; AAMI rating; critical zones; seam performance
SMMS / SMMMSComposite with two or three meltblown layers between spunbond facesMore design flexibility in distributing fine-fiber layersSame verification as SMS; do not infer protection level from layer count

Bottom line

Material construction can help explain how a gown is designed. Only labeling and applicable test evidence can establish how the finished gown is represented to perform.

Material construction is not the same as an AAMI level

ANSI/AAMI PB70 classifies protective apparel by liquid-barrier performance. The U.S. Food and Drug Administration recognizes this system for medical gowns, and CDC/NIOSH summarizes the associated tests.

Levels 1 through 3 use water-resistance tests. Level 4 uses a viral-penetration test for gowns. CDC/NIOSH cautions that the water tests used for Levels 1–3 cannot be treated as proof of impermeability, and their results should not be assumed to correlate with viral-penetration performance.

The classification applies to the finished garment and its critical zones, not merely a fabric swatch or a material acronym. Seams and other construction details matter.

Sources: FDA medical-gown guidance · CDC/NIOSH protective-clothing standards

AAMI isolation gown levels: Level 1 vs. Level 2 vs. Level 3 vs. Level 4

AAMI levelBarrier categoryCore PB70 test requirementFDA examples of settings or tasks
Level 1Minimal riskAATCC 42 spray-impact penetration: water impact on the material surface must be no more than 4.5 gBasic care, standard isolation, visitor gown, standard medical unit
Level 2Low riskAATCC 42 no more than 1.0 g, plus AATCC 127 hydrostatic pressure of at least 20 cmBlood draw, suturing, intensive care unit, pathology laboratory
Level 3Moderate riskAATCC 42 no more than 1.0 g, plus AATCC 127 hydrostatic pressure of at least 50 cmArterial blood draw, IV insertion, emergency room, trauma
Level 4High riskASTM F1671 viral-penetration test for gowns: no penetration at 2 psi (13.8 kPa) using Phi-X174 bacteriophageLong, fluid-intensive procedures; surgery; pathogen resistance; suspected infectious diseases that are not airborne

Sources: FDA medical-gown guidance · CDC/NIOSH protective-clothing standards

How to read the levels correctly

  • A higher level indicates more demanding standardized barrier testing; it does not mean the gown is automatically the best choice for every task.
  • Level 1 is not simply "bad," and Level 4 is not automatically "best." The correct choice matches the anticipated exposure.
  • Levels 1–3 measure water resistance under specific methods. They do not establish viral-penetration resistance.
  • A gown's label should identify the applicable standard and level. Ask for supporting documentation when the intended use makes barrier performance important.

Surgical gown, surgical isolation gown, and non-surgical isolation gown

The names are not interchangeable.

Non-surgical isolation gown

FDA describes non-surgical isolation gowns as Class I devices intended for minimal- or low-risk patient-isolation situations. They are not worn during surgical procedures, invasive procedures, or medium- to high-risk contamination situations.

Surgical isolation gown

Surgical isolation gowns are Class II devices intended for medium- to high-risk situations where there is a need for larger critical zones than those of a traditional surgical gown. FDA states that all areas of a surgical isolation gown except bindings, cuffs, and hems are considered critical zones and must meet the labeled barrier level, including seams.

Surgical gown

Surgical gowns are sterile Class II devices worn during surgical procedures. Their critical zones are defined differently from those of surgical isolation gowns.

For a real-world purchase, confirm the exact product type rather than relying on the word "gown" alone.

Source: FDA medical-gown guidance

How to choose an isolation gown

CDC guidance emphasizes matching PPE to the nature of the interaction, anticipated contact with infectious material, and the possibility that blood or body fluids could penetrate the garment. A practical review should include the following.

1. Start with the hazard and task

Consider the type, volume, and duration of expected exposure. Will there be splashes, sprays, pressure, leaning, kneeling, or prolonged contact with fluids? Physical actions can create pressures that differ from laboratory conditions.

2. Confirm the product type and intended use

Check whether the label identifies a non-surgical isolation gown, surgical isolation gown, or surgical gown, and whether the stated intended use matches the planned task.

3. Verify the barrier classification

Look for the ANSI/AAMI PB70 level and ask which test methods support it. Do not infer the level from PP, SMS, SMMS, SMMMS, fabric weight, or a marketing phrase.

4. Examine coverage and construction

Review length, sleeve and cuff design, neck and waist closures, back coverage, reinforced areas, and seams. Barrier material is useful only where it covers the wearer and remains properly positioned.

5. Consider comfort and work conditions

Breathability, air permeability, heat stress, mobility, noise, fit, and compatibility with gloves and other PPE can affect correct, continuous use.

6. Review shelf life, storage, and instructions

Check the manufacturer's labeled shelf life, storage conditions, package integrity, and instructions for use. Confirm that documentation applies to the exact model being purchased.

7. Follow the facility's risk assessment

Healthcare facilities should use their infection-prevention, occupational-safety, and clinical procedures to select PPE. This guide is educational and does not replace a task-specific risk assessment or manufacturer instructions.

Sources: CDC/NIOSH protective-clothing selection guidance · CDC isolation-precautions guidance

Common purchasing mistakes

Assuming "SMS" means Level 3

SMS describes a material structure. The same broad structure can be used in products with different weights, treatments, seams, designs, and performance claims.

Comparing only fabric weight

Basis weight can influence the design, but it does not independently establish barrier performance, comfort, or durability.

Ignoring seams and critical zones

A fabric may perform differently from a finished gown. Seam type, seam placement, closures, and zone coverage must support the labeled performance.

Treating "fluid resistant" as a complete specification

The phrase is incomplete without a cited test method, acceptance criterion, product type, and intended use.

Selecting the highest level for every situation

Overprotection can add heat and burden without improving task suitability. Underprotection creates obvious risk. Selection should be exposure-based.

Frequently asked questions

What does SMS stand for in isolation gowns?

SMS stands for spunbond–meltblown–spunbond. It describes a layered nonwoven material with a fine-fiber meltblown layer between two spunbond layers.

Is SMS better than PP?

Not universally. SMS offers a different layered construction, while "PP" often refers broadly to spunbond polypropylene. The better choice depends on the task, tested barrier performance, coverage, seam construction, comfort, and intended use.

Is an SMS gown waterproof?

Do not assume so. SMS construction alone does not establish impermeability. Verify the product's stated standard, test method, acceptance result, and intended use.

Does SMS automatically mean AAMI Level 3?

No. An AAMI level is based on standardized performance testing of the finished gown and its critical zones. Material terminology alone does not establish the rating.

What is the difference between SMS, SMMS, and SMMMS?

The acronyms describe the sequence and number of spunbond and meltblown layers. SMS has one meltblown layer, SMMS has two, and SMMMS has three between spunbond outer layers. Layer count alone does not determine the AAMI level.

What is the difference between AAMI Levels 1, 2, 3, and 4?

They represent progressively more demanding barrier-performance categories. Levels 1–3 use water-resistance tests with different acceptance criteria. Level 4 gowns use a viral-penetration test. The appropriate level depends on anticipated exposure.

Is AAMI Level 4 always the safest choice?

It is the highest PB70 barrier category, but appropriate PPE selection is task-specific. Facilities must consider exposure, comfort, fit, ergonomics, and compatibility with other PPE.

What documentation should a buyer request?

Request the exact product's intended use, AAMI PB70 level where applicable, test methods and reports, critical-zone and seam information, manufacturer instructions, shelf-life information, and storage requirements.

Key takeaways

  • PP and SMS describe material construction; AAMI levels describe tested performance.
  • SMS contains spunbond outer layers and a meltblown middle layer; SMMS and SMMMS contain additional meltblown layers.
  • More layers do not automatically mean a higher AAMI rating.
  • Levels 1–3 use water-resistance tests; Level 4 gowns use viral-penetration testing.
  • Gown choice should match the task, expected exposure, critical-zone coverage, seams, fit, comfort, and manufacturer instructions.
  • Buyers should verify claims for the exact finished product—not rely on acronyms or marketing language.

Sources and further reading

  1. U.S. Food and Drug Administration — Medical Gowns
  2. CDC/NIOSH — Standards and Specifications for Protective Clothing
  3. CDC/NIOSH — Considerations for Selecting Protective Clothing
  4. CDC — Isolation Precautions: Summary of Recommendations
  5. Peer-reviewed review — Isolation gowns in health care settings
  6. OSHA — Personal Protective Equipment

This guide is for general educational purposes. PPE selection should follow the applicable manufacturer instructions, workplace risk assessment, infection-prevention procedures, and regulatory requirements.